1. Which is the first equipment seen in the substation while coming from transmission system:
a) Circuit breaker
b) Lightning arrester
c) Current transformer
d) Transformer
2. Gas Insulated Substation is employed where:
a) Where there is less space available
b) For high altitude substations
c) In terrain region
d) All the above
3. A bus coupler circuit breaker is utilized in a substation for:
a) Joining the transmission line with station bus-bar
b) Joining main and transfer bus in a substation
c) Joining the generator with transfer
d) Joining the neutral of the generator with earth
4. Which of the gas is used in gas insulated substation:
a) Nitrogen + SF6
b) Hydrogen + SF6
c) SF6
d) None of the above
5. Which of the following bus-bars arrangement is more reliable and flexible:
a) Main and transfer bus scheme
b) One-and-half breaker scheme
c) Double main busbar scheme
d) Single busbar scheme
6. What is the maximum transmission voltage substation in India:
a) 400 kV
b) 500 kV
c) 750 kV
d) 1000 kV
7. A busbar is rated by:
a) Current only
b) Voltage only
c) Current, voltage and frequency
d) Current, voltage, frequency and short circuit current
8. In a substation current transformers are used to:
a) Measuring purpose
b) Protection purpose connecting to relays
c) Both (a) and (b)
d) None of the above
9. Step potential and Touch potential is associated with:
a) High voltage transmission
b) Earthing of the substation
c) Voltage rise in the substation
d) Communication systems
10. It is the minimum clearance required between the live conductors and maintenance operators limit:
a) Ground clearance
b) Phase cearance
c) Sectional clearance
d) None of the above
a) Circuit breaker
b) Lightning arrester
c) Current transformer
d) Transformer
2. Gas Insulated Substation is employed where:
a) Where there is less space available
b) For high altitude substations
c) In terrain region
d) All the above
3. A bus coupler circuit breaker is utilized in a substation for:
a) Joining the transmission line with station bus-bar
b) Joining main and transfer bus in a substation
c) Joining the generator with transfer
d) Joining the neutral of the generator with earth
4. Which of the gas is used in gas insulated substation:
a) Nitrogen + SF6
b) Hydrogen + SF6
c) SF6
d) None of the above
5. Which of the following bus-bars arrangement is more reliable and flexible:
a) Main and transfer bus scheme
b) One-and-half breaker scheme
c) Double main busbar scheme
d) Single busbar scheme
6. What is the maximum transmission voltage substation in India:
a) 400 kV
b) 500 kV
c) 750 kV
d) 1000 kV
7. A busbar is rated by:
a) Current only
b) Voltage only
c) Current, voltage and frequency
d) Current, voltage, frequency and short circuit current
8. In a substation current transformers are used to:
a) Measuring purpose
b) Protection purpose connecting to relays
c) Both (a) and (b)
d) None of the above
9. Step potential and Touch potential is associated with:
a) High voltage transmission
b) Earthing of the substation
c) Voltage rise in the substation
d) Communication systems
10. It is the minimum clearance required between the live conductors and maintenance operators limit:
a) Ground clearance
b) Phase cearance
c) Sectional clearance
d) None of the above